Transmitter & electrical calibration

Transmitter, Loop & HART / Fieldbus Calibration

Pressure, temperature and electronic transmitter calibration with HART, Profibus and Foundation Fieldbus communication — plus electrical measurement for 4–20 mA loops, switches and RTD inputs.

Smart transmitters, done right

CML Enterprises provides pressure, temperature and electronic transmitter calibration services and certification using high-accuracy, all-in-one Beamex MC6 calibration equipment. The MC6 combines calibrator and communicator, so we can test the analog output and work with the transmitter’s digital configuration in one setup. All calibration and certification is traceable to NIST.

For every transmitter we perform inspections, initial (as-found) tests and a full multi-point calibration. With extensive transmitter knowledge, we can repair and offer solutions for transmitters that no longer meet the necessary standards.

Communication protocols

HART

Calibration and trim of HART pressure and temperature transmitters.

Profibus

Calibration of Profibus field instruments.

Foundation Fieldbus

Calibration of Foundation Fieldbus field instruments.

Electrical measurement capabilities

Our calibration scope includes electrical measurement for loop and instrument work:

  • Current (including 4–20 mA loops)
  • Voltage
  • Frequency
  • Switch testing
  • RTD measurement

Transmitter types

  • Electronic pressure transmitters
  • Differential pressure (DP) transmitters — including critical-service DP transmitters
  • Temperature and RTD transmitters
  • Electronic transmitters and controllers
  • Pneumatic controllers, valves and positioners
  • Recorders and chart recorders

Published ranges

Pressure transmitters

RangePublished accuracy
Up to 160 inH₂O (inches water column)±0.01% of full scale
−14.5 to 300 psi±0.005% of full scale
0 to 9,000 psi±0.007% of full scale
Above 9,000 psi±0.25% of full scale

Temperature transmitters

RangePublished accuracy
−50 °C to 350 °C (−58 °F to 662 °F), °F or °C±0.01 °C

Test points

  • 3-point up & down procedure
  • 5-point up & down procedure
  • Custom-point up & down procedure

Field-proven on critical systems

CML supplies Argonne National Laboratory with valves and instrumentation and provides ongoing calibration service there. At Argonne, CML calibrated differential pressure transmitters on critical systems used to protect personnel and equipment — inside the tight window of a facility that runs 24/7. On another Argonne project, our team calibrated several unique pressure transmitters of varying types, many in difficult-to-reach locations, over two days. Read more about our laboratory and research work.

Read the Argonne Customer Success Story (PDF) (PDF, 968 KB)

Further reading

Calibrating WirelessHART transmitters (Beamex) (PDF, 144 KB)
Calibrating smart instruments (Beamex) (PDF, 1.0 MB)
Calibration in hazardous areas (Beamex) (PDF, 324 KB)

Calibrate your transmitters on-site

HART, Profibus and Foundation Fieldbus transmitters, DP cells and loops. Tell us how many and where.